Nanyang Technological University
Design and application of a 20 kW 50 kHz three-phase four-wire T-type SiC inverter
Abstract
dc:description.abstractDue to the ever-increasing power demands and the desire to reduce carbon footprints, conventional fossil fuel-based energy generation is gradually being replaced by distributed generation systems, which are typically composed of renewable energy and energy storage systems. In distributed systems that support single-phase sources and loads, a three-phase four-wire (3P4W) grid connection is typically employed. In this configuration, the 3P4W DC/AC inverter, serving as a bridge between DC and AC, plays a critical role. First, it determines the energy conversion efficiency between DC and AC. Additionally, it must be compatible with both grid-connected and standalone operational modes while maintaining high power quality. Furthermore, as the only interface with the grid in a LVDC (low-voltage direct current) microgrid, the 3P4W inverter needs to monitor the grid status, estimate grid impedance, and even transmit grid frequency information to harness energy from the LVDC microgrid to enhance the grid inertia. Although considerable research has been conducted on improving the inverter performance, most of them focus on three-phase three-wire (3P3W) configurations, and many existing studies still leave room for improvement. Therefore, this thesis aims to present a comprehensive discussion on the design and application of a 3P4W 20 kW 50 kHz SiC T-type inverter with enhanced performance. First, the inverter hardware design is discussed. Although using SiC devices offers significant benefits in terms of system efficiency and power density, they also present specific challenges, such as transient vds overvoltage issues caused by hard-switching turn-off. To address these challenges, a symmetrical layout scheme is adopted to form a T-type bridge-leg. Additionally, ceramic decoupling capacitors are placed to further reduce the PCB routing inductance. For verifications, the double pulse test (DPT) demonstrated that the vds spike can be reduced by around 20% at a 40 A hard-switching turn-off condition. Building on this design, the developed SiC T-type inverter achieves a power density of 1.8 kW/L and peak efficiencies of 99.22% and 99.11% in rectifier and inverter modes, respectively. Based on the developed SiC T-type inverter hardware, it is essential to guarantee the neutral-point voltage balancing (NPVB). However, conventional NPVB methods designed for three-phase three-wire (3P3W) three-level (3L) inverters, such as commonmode (CM) voltage injection, cannot be directly applied to 3P4W systems due to the neutral wire, which inevitably brings undesirable CM voltages and CM currents. Although dipolar modulation techniques have been used for 3P4W 3L inverters to balance the neutral-point (NP) voltage, these methods compromise power quality and system efficiency. To address these challenges, we proposed a minimally injective carrier-based NPVB method for the developed 3P4W SiC T-type inverters, ensuring voltage balancing in the split capacitors while maintaining high output power quality. Building on the proposed NPVB control, the closed-loop control schemes for standalone and grid-connected operational modes are then designed. To damp the inherent LC and LCL resonant peaks, digital active damping (DAD) schemes are carefully designed. Specifically, a capacitor-voltage positive-proportional-feedback DAD (CV-PP-DAD) method is proposed to extend the effective damping region and improve transient response in the standalone mode. Additionally, a capacitor-voltage negative-derivativefeedback DAD (CV-NDF-DAD) method is adopted to damp the LCL resonance in the grid-connected mode. Building on the damped system, the designed proportional repetitive (PRE) outer-loop controllers can offer significant advantages in both harmonic compensation and computational efficiency. For verification, the experimental results evaluated the performance of the designed closed-loop control schemes, where the total harmonic distortion (THD) levels of load voltages and grid currents remain below 1% in the standalone mode and grid-connected mode, respectively. Based on the developed hardware and closed-loop control schemes, we can explore the potential applications of the developed T-type SiC inverter. The first application is grid impedance estimation (GIE). Conventional active GIE methods, such as the PQ variation method, intentionally introduce power disturbances around the system’s steady-state operating point. However, this can result in undesired reactive power being injected into the grid, and its accuracy may be affected by phase-locked loop (PLL) phase angle variations. To address these challenges, we proposed a noninvasive GIE method that leverages the inherent operating characteristics of the PLL, ensuring accurate estimation results across diverse conditions. Another potential application arises when the developed inverter is used in a distributed LVDC microgrid. By transmitting grid frequency through DC bus voltage variations, the internal units within the LVDC microgrid can be mobilized and independently configured to enhance grid inertia without the need for communication. The overall connection and relationship of the performed research are summarized as: the hardware design lays the foundation for the control implementation. With the hardware and NPVB strategy established, the focus shifts to closed-loop control and active damping design in both standalone and grid-connected operation. Finally, based on the developed inverter, its two potential applications are introduced. As the trend of renewable integration continues, new opportunities will emerge in moreelectronics- based power systems. In this process, the DC/AC inverters will play an increasingly important role, taking on greater responsibilities and facing more challenges, which will need to be addressed through further research efforts.
Degree
thesis:*- College dc:contributor.school
- School of Electrical and Electronic Engineering
- Grantor dc:publisher
- Nanyang Technological University
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Yang, Haoxin
- Advisor dc:contributor.supervisor
-
- Tang Yi
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/10356/200410