Back to search

Nanyang Technological University

Gas composition detection

Abstract

dc:description.abstract

A basic development history of gas component detection including traditional method, different devices and outcomes will be introduced briefly. And the research method, data analysis process, and final conclusion of this experiment will be elaborated in detail. This article briefly reviews the development trajectory of gas composition detection technology, including traditional methods, different instrument configurations, and corresponding performance results. This paper systematically expounds the research framework, data analysis process and core achievements of the experimental study on the detection of hydrogen sulfide (H2S) by mid-infrared spectroscopy. The experimental plan was strictly carried out in accordance with the principles of standardization and operational norms, using nitrogen (N2) as the reference gas to characterize the absorption behavior of H2S.A dedicated detection system integrating mid-infrared light sources, optical choppers, gas flow controllers and photoelectric conversion modules has been established. The operation mechanism includes emitting mid-infrared radiation from the target gas, modulating the light signal through a chopper, converting the attenuated light into an electrical signal using a detector, then processing the signal through a lock-in amplifier, and data acquisition and visualization through a computer terminal. To ensure the robustness of the experimental results, the experiment was repeated multiple times under controlled conditions, and the H2S concentration was systematically adjusted to strictly stabilize the gas flow parameters. Environmental noise interference has been mitigated through shielding measures (such as wrapping the optical path with tin foil). The data processing after the experiment, using the analysis tool based on python, led to the derivation of the absorption coefficient and absorption spectrum of H2S. It was found that a characteristic absorption peak was at 1375.50 cm-1, and the maximum absorbance value was 0.3672. In this study, by establishing a mid-infrared spectroscopy detection system, the characteristic absorption peak of H₂S at 1375.50 cm⁻¹ and the detection limit of 5 ppm were clarified. This not only verified the effectiveness of mid-infrared spectroscopy technology in the precise identification of H₂S. It provides a reusable technical framework for the subsequent qualitative differentiation and quantitative calculation of multi-component mixed gases (such as H₂S/SO₂/CO₂), and has practical application value for industrial safety monitoring and environmental pollutant detection.

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Grantor dc:publisher
Nanyang Technological University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Bohan
Advisor dc:contributor.supervisor
  • Wang Qijie

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10356/205258

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Liu, Bohan. Gas composition detection. Nanyang Technological University, 2025. https://hdl.handle.net/10356/205258