Fabrication and characterization of barium strontium titanate film based biosensor

Abstract

dc:description.abstract

In this project, biosensors based on a sol-gel derived Barium Strontium Titanate (BST) composite film are studied. Poly(TMS-r-NHS) [TMS: 3-(trimethoxysilyl)propyl methacrylate; NHS: N-hydroxysuccinimide] is used to modify the BST surface for protein immobilization. Two types of biosensors were developed and investigated. First, Bovine Serum Albumin (BSA) was immobilized on the poly(TMS-r-NHS) followed by anti-BSA. On the second type of biosensors, cloned Epstein-Barr virus (EBV) was imlTIobilized on the poly(TMS-r-NHS) followed by anti-EBV. Significant impedance increlnents were observed on both biosensors. These impedance increments were attributed to three factors.

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tan, Lay Im
Advisors dc:contributor.supervisor
  • Gan-Yap Yik Yuen
  • Tan Ooi Kiang

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Tan, L. I. (2006). Fabrication and characterization of barium strontium titanate film based biosensor. Master’s thesis, Nanyang Technological University, Singapore.

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-29
Source record
OAI-PMH GetRecord
citation

Tan, Lay Im. Fabrication and characterization of barium strontium titanate film based biosensor. 2006. https://doi.org/10.32657/10356/20679