Back to search

Nanyang Technological University

Software-hardware co-design for biomedical signal analysis and human-machine interface

Abstract

dc:description.abstract

With the increasing ageing population, there is a surging need for wearable edge devices that provide continuous biomedical monitoring and analysis at home. On the other hand, human-machine interfaces (HMIs) suitable for implementation in edge devices also draw great attention because they offer a practical means of interacting with machines and bring significant convenience to daily life. Edge devices, however, typically compromise performance due to system-level constraints such as tight form-factor limits, restricted power budgets, and stringent end-to-end latency requirements. This thesis addresses these challenges through co-design of algorithms and their digital/analog hardware implementations, framing the objective as achieving target task accuracy and robustness subject to device-level constraints on energy, latency, and memory footprint. The first part of this thesis aims to develop biomedical signal-processing methods that are hardware-aware from the outset and validated on deployable FPGA platforms. Two representative cases are presented: (i) electrocardiogram (ECG) classification that exploits compute/data reuse and low-precision arithmetic for efficient mapping; and (ii) respiratory-sound analysis under scarce and imbalanced labels using supervised-contrastive learning (SCL), carried through quantization-aware training (QAT) to preserve deployment fidelity. On MIT-BIH ECG, a dynamically biased long short-term memory (DB-LSTM) and a recurrent convolutional neural network (QRCNN) support INT4/INT8 quantization with pipelined reuse, yielding up to 98.08% validation accuracy on a five-class task while consuming <60% of the dynamic power of a reference quantized CNN on an Artix-7 FPGA. The proposed model uses ∼25% fewer trainable parameters and matches the classification accuracy of state-of-the-art designs while delivering ∼10× lower power. For respiratory sounds, the SCL+QAT pipeline attains a 0.8725 total score (classification accuracy and runtime latency) with 16 ms end-to-end latency on a ZCU102 FPGA, reducing model size by ∼40% and latency by ∼70% relative to a standard software pipeline and thereby meeting real-time monitoring requirements. The proposed framework achieved the highest total score and, to the best of our knowledge, is the first to realize real-time respiratory-sound classification on edge hardware. The second part of this thesis presents a circuit-algorithm co-design framework for a learnable analog front-end (AFE) in audio signal classification. Designing the AFE and the back-end classifier separately is common but suboptimal at the system level; instead, we jointly optimize the classifier together with the AFE’s transfer function to target a system-level optimum. Concretely, the transfer-function parameters of an analog bandpass filter (BPF) bank are tuned within a signal-to-noise ratio (SNR)-aware training loop using a co-design loss LBPF, enabling superior co-optimization of both the filter bank and the classifier while preserving circuit realizability. Implemented in the open-source SKY130 130 nm CMOS process, this is the first reported learnable analog front-end using a circuit-algorithm co-design strategy. For keyword spotting, the learned AFE co-optimized with a compact depthwise-separable CNN (DSCNN) sustains 90.5−94.2% accuracy across 5 − 20 dB input SNR with only 22k classifier parameters, while reducing analog power by 8.7% and capacitor area by 12.9% versus a conventional fixed AFE; this noise-robust accuracy is among the highest reported for comparable state-of-the-art designs. In summary, biomedical signal analysis and HMI are pivotal edge-device application domains and increasingly critical to supporting an ageing population. Across these cases, the proposed co-design methodology consistently delivers high task accuracy at substantially lower power and latency, enabling practical, continuous, on-device multimodal signal inference.

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Grantor dc:publisher
Nanyang Technological University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hu, Jinhai
Advisor dc:contributor.supervisor
  • Goh Wang Ling

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-29
Source record
OAI-PMH GetRecord
related terms
citation

Hu, Jinhai. Software-hardware co-design for biomedical signal analysis and human-machine interface. Nanyang Technological University, 2026. https://doi.org/10.32657/10356/212799