Nanyang Technological University
Measurement of diesel particulate and its volatile organic compound
Abstract
dc:description.abstractIncreasing concern on health related effects related due to inhalation of diesel particulates has led to increasingly stringent legislation on particulate emissions from diesel-powered vehicles. At present, the conventional filtration method specified by the US Environmental Protection Agency (EPA) is used to determine particulate emissions gravimetrically which is integrated over a transient test cycle. But this time-consuming and labor-intensive method cannot produce real-time particulate measurements, especially during the transient engine operations. Therefore, the development of real-time particulate measurement techniques is crucial not only in providing an alternative to the tedious and time-consuming dilution tunnel procedure but also in allowing real-time particulate analysis.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- He, Yongsheng.
- Advisor dc:contributor.supervisor
-
- Chan, Siew Hwa
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Nanyang Technological University
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10356/2147