Design of a dB-linear variable gain amplifier with high linearity for ultrasound imaging in 110nm CMOS

Abstract

dc:description.abstract

The variable gain amplifier (VGA) used for time-gain compensation (TGC) in medical ultrasound imaging must meet multiple strict requirements, combining a wide dB-linear gain range, low noise and minimum distortion, a gain-independent bandwidth, and an area compact enough for multi-channel integration. Existing subthreshold current steering VGAs typically trade one of these metrics against the others, and few had reported the attainment of noise and linearity under full process variation. This dissertation presents a fully differential, two-stage cascaded dB-linear VGA in an XFAB 110nm CMOS process, developed at the Agency for Science and Technology (A*STAR) Institute of Microelectronics (IME), Singapore, and taped out in March 2026. The design addresses the noise, linearity, and inter-stage coupling problems that have limited earlier subthreshold current-steering VGAs. A 1:2 cascode current mirror is placed between the input pair and the common-gate stage so that the effective transconductance doubles; the input-referred noise contribution of every transistor after the mirror drops by a factor of four, cutting best-case IRN by 46.1% and worst-case IRN by 64.7% relative to the same topology without the mirror. A cascode protection transistor is stacked above the subthreshold steering device to clamp its drain voltage well above 4𝑉𝑇, which keeps the exponential 𝐼-𝑉 relation accurate and reduces single-ended HD2 by about 15 dB; the overall worst-case THD improves by 29.4%. Two super source follower (SSF) buffers couple the cascaded stages while maintaining stable Common Mode Feedback (CMFB) loops and sufficient output drive at all gain settings. With these three modifications, subthreshold current steering becomes a viable option for the noise and linearity levels that ultrasound imaging requires. Post-layout simulation, PVT corner sweeps, and a 300-run Monte Carlo analysis confirm a 44.24 dB dB-linear gain range with ±0.74 dB error, a constant 15.51 MHz −3 dB bandwidth, 11.58 nV/√Hz IRN at 5 MHz and maximum gain, worst-case THD of −43.2 dB at maximum gain and full swing, and 2.823 mW from a 1.5 V supply, all at the typical corner. The core occupies only 0.02 mm², the smallest among six recently published continuous-control dB-linear VGAs, and is among the first to validate both noise and linearity across full PVT and Monte Carlo in a 110 nm node, providing a practical building block for portable, multi-channel ultrasound front-ends.

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Grantor dc:publisher
Nanyang Technological University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tao, Siming
Advisor dc:contributor.supervisor
  • Goh Wang Ling

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10356/215812

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Tao, Siming. Design of a dB-linear variable gain amplifier with high linearity for ultrasound imaging in 110nm CMOS. Nanyang Technological University, 2026. https://hdl.handle.net/10356/215812