Back to search

Nanyang Technological University

A feasibility study of a capsule-integrated bleeding detection module in a simulated gastric environment

Abstract

dc:description.abstract

Ingestible electronic capsules provide a promising route for continuous monitoring in the GI tract and have the potential to enable pathological sensing. This dissertation focuses on the experimental evaluation and data-driven algorithmic development of a bleeding detection module for a gastric-resident ingestible capsule, investigating its feasibility for blood-state recognition in a dynamic, gastric-like environment subject to severe dietary interferences. Within this framework, a miniaturized optical sensing prototype featuring an AS7343 spectral sensor was utilized to collect bleeding-related spectral data in a dynamic gastric simulator. Experimental results showed that the measured optical signals were strongly affected by gastric-like motion, transient channel filling, bubbles, and dietary interference. To address this challenge, continuous recordings were organized into temporal-spectral samples for subsequent analysis. As an interpretable reference, a ratio-based baseline method was first evaluated. To improve robustness under motion and interference, a dual-template relative-feature MLP model was further developed. The results showed that the proposed MLP model achieved an accuracy of 99.7% under pure conditions and maintained 95.0% accuracy across heterogeneous dietary interference backgrounds. Furthermore, the system demonstrated a highly sensitive physical LOD of 0.1 mL/min for active hemorrhage, demonstrating the advantage of temporal-spectral modeling for robust bleeding detection in dynamic gastric environments. Overall, this work establishes the engineering feasibility of capsule-integrated optical sensing for bleeding detection and provides an experimental and methodological foundation for further development of gastric-resident pathological sensing.

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Grantor dc:publisher
Nanyang Technological University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jing, Zhiyuan
Advisor dc:contributor.supervisor
  • Hen-Wei Huang

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10356/218921

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Jing, Zhiyuan. A feasibility study of a capsule-integrated bleeding detection module in a simulated gastric environment. Nanyang Technological University, 2026. https://hdl.handle.net/10356/218921