Investigation of via2 chain test structure high resistance failure

Abstract

dc:description.abstract

This report covers an investigation into the failure mechanism behind the via resistance failure in an electrical test structure. Intermittent high resistance failures occur in the via 2 chain test structure for a certain process. The failed wafers showed marginally high resistance at max 4 ohm/via (max specification: 1.2 ohm/via).

Degree

thesis:*
College dc:contributor.school
School of Electrical and Electronic Engineering
Year dc:date.issued
2002