Back to search

Nanyang Technological University

An optimal dose-finding technique based on bayesian decision theory for oncology phase I/II clinical trials

Abstract

dc:description.abstract

A phase I dose-finding clinical trial has always been a challenge to find a safe dosage, given a very limited sample size and shorter timeframe. This is particularly important for cancer trials as new experimental drugs could be cytotoxic and life threatening if too high a dose is given or an inaccurate estimated dose level is thought to be safe and continues to be used for subsequent Phase II and III trials. In this research work, a new approach is proposed that help to improve on the current Phase I design in obtaining a better reliability of finding a safe dosage and using fewer patients to obtain the results. The proposed design utilizes a Bayesian decision theory to look at either single event of toxicity or a combined event of both toxicity and efficacy to obtain an optimal dose for a Phase VII clinical trial study. The method assumes binary outcomes for all of these events which give rise to a multinomial likelihood. A decision table is defined with utility values attached to each possible decision. One of the unique attributes of this design is that it has a relationship between these utility values and the target probability associated with a toxicity and efficacy outcomes. By eliciting this target value from the clinical investigator, along with their beliefs on the relative importance of efficacy and toxicity in their trial, appropriate trial specific utility values may be obtained. Due to this interaction between the utility and the target value, the process of finding the optimal dose can be escalated. In addition, the design proposes a stopping criterion based on Bayesian inference to bring the trial to an early completion with a minimum number of patients. The results show promising performance by the proposed design and it has a competitive edge over some of the well-established phase I designs where the comparison is based on simulation run using various clinical scenarios. The design is also tested using actual clinical study data to obtain the optimal dose at the correct dose level using fewer cohorts of patients.

Degree

thesis:*
College dc:contributor.school
School of Mechanical and Aerospace Engineering
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Loke, Yee Chong
Advisor dc:contributor.supervisor
  • Cai Yiyu

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Loke, Y. C. (2008). An optimal dose-finding technique based on bayesian decision theory for oncology phase I/II clinical trials. Doctoral thesis, Nanyang Technological University, Singapore.

Chain of custody

source
Harvested from
Nanyang Technological University
Base URL
dr.ntu.edu.sg/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Loke, Yee Chong. An optimal dose-finding technique based on bayesian decision theory for oncology phase I/II clinical trials. 2008. https://doi.org/10.32657/10356/41746