Abstract
dc:description.abstractThis research is concerned with condition monitoring and fault diagnosis of the piston of the water hydraulic motor by vibration signal analysis. Vibration signatures are obtained from the casing of the water hydraulic motor. The size and locations of straight-line cracks on the piston were introduced for the experiments. The lengths of the short piston cracks and long piston cracks are 5mm and 10mm, respectively. They are in the front and back sections of the piston, respectively. There are four kinds of piston cracks, i.e. back long crack (BLC), back short crack (BSC), front long crack (FLC) and front short crack (FSC).
Degree
thesis:*- College dc:contributor.school
- School of Mechanical and Aerospace Engineering
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chen, Hanxin
- Advisor dc:contributor.supervisor
-
- Chua Soon Keong, Patrick
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Nanyang Technological University
Identifiers
dc:identifier.*- Identifier URI
- https://hdl.handle.net/10356/5333
- Dc Identifier Citation
- Chen, H. (2005). Dynamic analysis and fault diagnosis of a water hydraulic motor. Doctoral thesis, Nanyang Technological University, Singapore.