dc:description.abstractThe CUSUM chart is very effective in the detection of small or moderate process shift as compared to the Shewhart control chart commonly use in the industry. However the run-rules concept use extensively in the Shewhart control chart has not been applied into the CUSUM chart. Thus the main objective of this dissertation is to study the integration of the CUSUM chart with the run rules implementation, and the optimisation of the parameters of the CUSUM chart so as to increase the effectiveness of detecting an out-of-control signal much faster than before. The computer simulation of the dissertation is written in C-programming language for the run-rules optimisation of the CUSUM chart parameters.
Degree
thesis:*- College dc:contributor.school
- School of Mechanical and Production Engineering
- Year dc:date.issued
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Loh, Teck Hee.
- Advisor dc:contributor.supervisor
-
- Wu, Zhang
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Nanyang Technological University
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10356/6092