Investigation of cooling efficiency of rim driven fans compared with conventional fans
Abstract
dc:description.abstractUnlike most conventional fans, rim driven fans are not driven by an axisymmetric shaft but instead by the rim itself, thereby removing the need for a shaft. This is thus more effective and economical for the purposes of cooling for various appliances. A thorough steady CFD analysis was performed for this quantitative investigation, including a grid independence study for verification of both mesh models of both the rim driven fan as well as the conventional fan. Using a standard k-ro turbulence model on FL VENT™, the numerical results will reflect the intricate aspects of convective heat transfer in both models along with their flow visualization. A cooling efficiency parameter was formulated to compare the effective heat flux removed from the heat source by the respective fans thereby directly reflecting the aspect of cost.
Degree
thesis:*- College dc:contributor.school
- School of Mechanical and Aerospace Engineering
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kanaparthi, Noel Anish
- Advisor dc:contributor.supervisor
-
- Basman Elhadidi
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10356/75951