North Dakota State University
Using Prescription Maps for In Field Evaluation of Parameters Affecting Spraying Accuracy of a Self-Propelled Sprayer
Abstract
dc:description.abstractAdvanced sprayer control systems aim to improve accuracy and reduce waste in spray application. The objective of this study was to determine an optimum prescription map cell size/resolution that is compatible with current technology. A prescription map with several cell sizes was created and tested in field conditions to evaluate the effect different cell size parameters have on spray accuracy. The outcomes show that the dependent variable cell width had the greatest effect on application accuracy (p-values < 0.05), followed by cell length, and that an optimum cell width of 1.5 m [4.92 ft], a length of 3.05 m [10 ft], and application speed of 10.3 km h-1 [6.4 mph] is recommended. To further refine this analysis, the testing should be expanded with the inclusion of a variety of manufacturers and equipment and a test prescription map with a truly randomized cell distribution to better reflect actual field conditions.
Degree
thesis:*- Grantor dc:publisher
- North Dakota State University
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mayer, John Christopher
Rights
dc:rights- Statement dc:rights
-
- NDSU Policy 190.6.2
- Licence dc:rights.uri
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10365/32744