NJIT
Membrane-based reactors for ozonolysis of organic pollutants in aqueous and gaseous streams
Abstract
dc:description.abstractMany gaseous and aqueous waste streams contain multiple organic pollutants at low concentration levels. It is not economical to recover and reuse these compounds; it would be advantageous to destroy them efficiently within the waste stream. This work employed ozone, a powerful oxidizing agent, in concert with a compact membrane-based phase-contacting device. Three types of membrane devices were studied: two of them (the single-phase membrane ozonator and the two-phase membrane ozonator) treated organic pollutants in wastewater, while the third (the integrated absorption-oxidation membrane ozonator) removed volatile organic compounds (VOCs) from a gaseous waste stream. In the single-phase membrane ozonator, the polluted wastewater stream was exposed to O_3/O_2 by means of a nonporous silicone capillary membrane. Experiments conducted to ascertain the effect of long-term exposure of O_3 on the membranes measured the permeability of O_2/N_2 across the membrane before and after exposure to O_3; the permeability of O_3 across the nonporous membrane was also experimentally measured and found to be four times that of oxygen. The removal of organic pollutants (phenol, acrylonitrile and nitrobenzene, feed concentrations -100ppm) from wastewater was studied experimentally. A mathematical model was proposed; numerical simulations of the model successfully predicted the performance of this membrane reactor. The two-phase membrane ozonator and the integrated absorption-oxidation membrane ozonator used an inert fluorocarbon (FQ medium as a liquid membrane and a reaction medium. Ozone has a very high solubility in this FC phase compared to that in water. The performance of the two-phase membrane ozonator was studied experimentally for the following compounds: phenol, nitrobenzene, acrylonitrile, toluene and trichloroethylene (TCE). A mathematical model was developed; the model predictions were close to the experimentally observed reactor performance. The two-phase membrane reactor showed higher rates of pollutant degradation than the singlephase membrane ozonator for nitrobenzene as a model pollutant (feed concentration ~120 ppm). Experimentally observed ozone utilization in the two-phase membrane ozonator for nitrobenzene as a model pollutant showed an ozone utilization rate > 15 for a feed concentration of ~120 ppm; and 0.1 for a feed concentration of 1400 ppm. The performance of the integrated absorption- oxidation membrane ozonator was studied for trichloroethylene (TCE) and toluene as representative VOCs. This reactor demonstrated that the two-phase ozonation concept can be successfully extended (with little modification to the membrane reactor) to treat gaseous waste streams with VOCs.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy in Chemical Engineering - (Ph.D.)
- Discipline thesis:degree_discipline
- Chemical Engineering, Chemistry and Environmental Science
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Shanbhag, Purushottam V.
- Contributors dc:contributor
-
- Kamalesh K. Sirkar
- Gordon Lewandowski
- Basil Baltzis
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/dissertations/1041