Back to search

NJIT

Biomechanical comparison of interosseous and subperiosteal flexor tendon reattachment

Abstract

dc:description.abstract

This study was undertaken to biomechanically compare the interosseous and subperiosteal distal flexor tendon reattachment techniques. Twenty New Zealand white rabbits underwent division of the right second and third hind limb profundus flexor tendon distal to the insertion of the superficial flexor. All tendons were repaired using the Kleinnert-Bunnell configuration with a 5-0 nylon tied over a cotton pad on the dorsum of the digit. In half of the animals, the second profundus was reattached into a hole in the middle phalanx and the third profundus was reattached after periosteal stripping of the middle phalanx. The other animals underwent subperiosteal repair of the second flexor and interosseous repair of the third. The limbs were immobilized for three weeks at which time 10 animals were sacrificed (Group 1), the limb disarticulated and frozen. The remaining (Group 2) were, following an additional five weeks, sacrificed and the limbs harvested and frozen. The limbs were thawed and the repaired tendons biomechanically tested to failure with an Instron, servo-hydraulic mechanical test system. RESULTS: Interosseous Subperiosteal Group 1 (3 weeks) 17 +/- 4 N 15 +/- 5 N Group 2 (8 weeks) 45 +/- 16 N 58 +/- 19 N Controls (3 weeks) and controls (8 weeks) produced mean and standard deviation values of 91 +/- 16 Newtons and 100 +/- 20 Newtons respectively. These results were analyzed with the ANOVA, Analysis of Variances method. No statistical differences were found between the interosseous and subperiosteal repair sites. It is concluded that both techniques were successful in attaining sufficient healing. The repaired tendon-bone interfaces were capable of withstanding physiologic loads.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering - (M.S.)
Discipline thesis:degree_discipline
Biomedical Engineering Committee

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Olin, Alisa Beth
Contributors dc:contributor
  • Clarence W. Mayott
  • David S. Kristol
  • Richard Clyde Parker

Subjects

dc:subject × 3

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/1671

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Olin, Alisa Beth. Biomechanical comparison of interosseous and subperiosteal flexor tendon reattachment. https://digitalcommons.njit.edu/theses/1671