Abstract
dc:description.abstract<p>A short-cut procedure has been developed for making calculations on a complex fractionation tower. A Simplification of the Thiele-Geddes plate-to-plate procedure provided the basis for the short-cut procedure. The application discussed in this paper is for a tower with a liquid sidestream drawoff in the rectifying section.</p><p>The tower was broken at the feed point and sidestream drawoff locations into three calculation sections. The fractionation in each tower section can then be represented by a rigorous series solution expressed in terms of absorption or stripping factors. These rigorous equations can then be simplified by the use of average absorption or stripping factors.</p><p>The short-cut procedure has two methods of determining the average stripping or absorption factors for each tower section. The one method uses the assumption of a linear profile of absorption or stripping factors based on end values in each section and is called the Stand-Alone Simplified Thiele-Geddes Method. The other method determines average absorption or stripping factor for each tower section from a force-fit to a rigorous plate-to-plate solution. This method is called the Force-Fit Thiele-Geddes Method and is suitable for accurate parametric studies around a base case rigorous solution.</p><p>Computer programs were prepared for the Thiele-Geddes plate-to-plate method and the stand-alone short-cut procedure. In addition, a computer program was written to obtain the force-fit fractions required for the Force-Fit Thiele-Geddes Method. Parametric cases were then run for a five-component debutanizer column, and the results of the short-cut method were compared with the rigorous solution for each case.</p><p>The results of these comparisons show the Stand-Alone Simplified Thiele-Geddes Method to be of suitable accuracy for preliminary design calculations. The Force-Fit Thiele-Geddes Method results in a higher degree of accuracy in most cases and is suitable for parametric studies on a final design. The degree of accuracy obtained from the Force-Fit Method is believed to be the highest available from a short-cut procedure.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Chemical Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Chemical Engineering and Chemistry
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Prickett, Richard David
- Contributors dc:contributor
-
- Ralph Ceccheti
- Edward Charles Roche, Jr.
- John E. McCormick
Subjects
dc:subject × 2Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/2025