Back to search

NJIT

Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals

Abstract

dc:description.abstract

<p>Safety procedures for performing geotechnical testing with hazardous and toxic materials, excluding radioactive wastes, are developed for the Flexible Wall Permeameter and the Atterberg Limits Tests. The tests were evaluated in detail to determine the critical points at which the technician would be exposed to the hazardous and/or toxic permeant. It was found that the following safety measures should always be taken; 1) the apparatus and all testing should be undertaken in a sliding sash hood using the proper face velocity, 2) air monitoring using a personal dosimeter and/or a detector tube is required to assure that the concentration of the permeant in the atmosphere does not exceed the Threshold Limit Value Time Weighted Average, 3) safety goggles must be worn at all times while in the laboratory, 4) protective gloves must be worn whenever handling the permeant or soils contaminated with the permeant, and 5) a properly fitting respirator that is specifically designed for the permeant being used should be readily available in case of an emergency.</p><p>If the Flexible Wall Permeameter cannot be placed in a sliding sash hood, the above protective measures are still followed, however, the following things are modified; 1) an open canopy type hood should be placed above the apparatus, 2) the reservoir on the apparatus is replaced with an air tight reservoir, 3) there is a more stringent requirement on the frequency of air monitoring, and 4) all venting lines and de—airing lines which are connected to the permeant are positioned under the open canopy hood.</p><p>To develop these procedures, properties of the permeant, chemical, such as; 1) solubility, 2) reactivity, 3) toxicity, 4) vapor pressure, and 5) its allowable exposure limits (Threshold Limit Values), were evaluated. A general chemical information form was developed to expedite data gathering and to allow a methodical determination of protective procedures for each individual chemical. For illustration purposes, this form is completed for: benzene, trichloroethylene, and phenols.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Environmental Engineering - (M.S.)
Discipline thesis:degree_discipline
Civil and Environmental Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tetla, Robert A.
Contributors dc:contributor
  • John R. Schuring
  • Dorairaja Raghu
  • Paul N. Cheremisinoff

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2083

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Tetla, Robert A.. Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals. https://digitalcommons.njit.edu/theses/2083