Abstract
dc:description.abstract<p>Measurements of the rate of absorption of ammonia in water have been made using a 4-inch diameter Lucite column With porcelain Raschig rings packed to a height of 3 feet, Tests were made with water rates of 462 and 695 lbs./ hr-ft<sup>2</sup> and a constant gas rate of 130 lbs/hr-ft<sup>2</sup> with liquid temperature verying from 72° F. to 110° F.</p><p>At constant liquid and gas rate, the mass transfer coefficient, Î<sub>G</sub>a, decreases with increasing liquid temperature and in represented by straight lines on plot of Î<sub>G</sub>a versus temperature. The variation of Î<sub>G</sub>a with liquid temperature ranged from 6,05 at 72° F. to 2.5 at 104° F. with a constant liquid rate of 462 lbs. /hr-ft<sup>2</sup> and a constant gas rate of 130 lbs./hr-ft<sup>2</sup>, At the same gas rate of 130 lbs./hr-ft<sup>2</sup>, Î<sub>G</sub>a varied from 6.55 at 78° F, to 5.28 at 100° F.</p><p>It was also found that Î<sub>G</sub>a increases with an increase in water rate, and may also be represented by straight lines on a log-log plot.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Chemical Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Chemical Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Patel, Chhotu B.
- Contributors dc:contributor
-
- John W. Axelson
- Joseph Joffe
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/2129