Back to search

NJIT

Electroretinogram modeling : parameter identification and intensity-response function fits

Abstract

dc:description.abstract

<p>Electroretinography testing provides many useful techniques for clinical diagnosis of the visual system. However, the interpretation of the electroretinogram data involves a great amount of subjectivity. The use of mathematical models and parameter estimation techniques to fit the electroretinogram data supply a non-subjective and more standard way for analysis of the electroretinogram data. Mathematical models provide a way of summarizing the information enclosed in the raw electroretinogram response into a small set of parameters that define the response.</p><p>This thesis presents a mathematical model for the electroretinogram response due to light stimuli. It also provides a non-subjective method for obtaining the parameters of an intensity-response function, known as Naka-Rushton function, using the parameters of the mathematical model which define the raw electroretinogram data, instead of quantifying the information from the raw electroretinogram.</p><p>The intensity-response function is an example of the use of the information provided by the electroretinogram to evaluate retinal sensitivity to light stimuli. The proposed method for obtaining the intensity-response function consists of fitting the raw electroretinogram responses with the mathematical model of the electroretinogram in order to obtain the parameters which represent each response. These parameters are then used to obtain the intensity-response function instead of having to manually measure the amplitude of each electroretinogram response which is very error prone.</p><p>Several subjects were used to obtain electroretinogram responses. Each response was fitted with the mathematical model. The parameters from the electroretinogram model were then used to obtain the intensity-response function, thus providing more consistent and less subjective results.</p><p>The intent of this thesis is not to reach any medical conclusions but to provide a method to aid in the clinical diagnosis of the visual system.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Electrical Engineering - (M.S.)
Discipline thesis:degree_discipline
Electrical and Computer Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Castro, Juan J.
Contributors dc:contributor
  • Andrew Ulrich Meyer
  • Stanley S. Reisman
  • Edward Joseph Haupt

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2402

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Castro, Juan J.. Electroretinogram modeling : parameter identification and intensity-response function fits. https://digitalcommons.njit.edu/theses/2402