Abstract
dc:description.abstract<p>Superheated mixtures of cyclohexane vapor and nitrogen gas were passed at various rates downward through a single tube condenser with the cooling water flowing countercurrently in an annular space outside the condenser.</p><p>The method of Colburn and Rougen for the design of cooler-condensers was applied and the calculated condenser lengths are compared to the experimental length.</p><p>Relatively good agreement with the design method was found for cases where there was little or no streamline flow of the gas-vapor mixture in the condenser. With increasing amounts of streamline flow* the design method tends to be increasingly conservative.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Chemical Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Chemical Engineering
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mruk, Stanley Anthony
- Kraemer, William Charles
- Contributors dc:contributor
-
- Jerome J. Salamone
- C. L. Mantell
- Joseph Joffe
Subjects
dc:subject × 2Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/2428