Back to search

NJIT

Effect of column diameter on mixing in water fluidized beds

Abstract

dc:description.abstract

<p>In this investigation, the effect of column diameter and flow rate on the mixing characteristics of fluidized beds were studied.</p><p>Tests were made on columns of 4, 6, 8 and 10 inches in diameter using water to fluidize glass beads of 0.0185 inches in diameter. The tests were run both at minimum and three times minimum fluidization. Step, impulse, and sinusoidal forcing signals were fed to the columns, using a sodium chloride solution as a tracer with the inlet and outlet concentrations being monitored continuously by a conductivity recorder.</p><p>The result of this study showed increased fluid dispersion with increasing column diameter. However, the best results were found using the step and impulse forcing signals. Only partial success was obtained using sinusoidal inputs.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering - (M.S.)
Discipline thesis:degree_discipline
Chemical Engineering and Chemistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schiesl, Donald P.
Contributors dc:contributor
  • Deran Hanesian
  • Angelo J. Perna
  • Hung T. Chen

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2439

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Schiesl, Donald P.. Effect of column diameter on mixing in water fluidized beds. https://digitalcommons.njit.edu/theses/2439