<p>Thrombus formation is one of the major problems in artificial heart development and its clinical applications. In order to improve the antithrombogenesis in the artificial ventricles, three aspects of investigation have been done in the laboratory.</p><p>1] the surface features and the surface defects on specially prepared samples made of polyurethane and silicon rubber were studied and analyzed by scanning electron microscopy ( SEM ), light microscopy and KEVEX Feature Analysis for understanding and controlling the blood contacting surface.</p><p>2] the polyurethane blood contacting surface with smooth surface fabricated by solution cast process, the material treatment, and the fabrication procedure are developed and evaluated by in vitro blood test.</p><p>3] the diaphragm housing junction ( DHJ ), the connector system and the sealing method are studied and redesigned.</p><p>The results indicated that the surface morphology could be controlled by varying fabrication conditions. Air bubbles, open craters, dust and gel particles were four important surface defects which could be reduced by material filtration and quality control in the cast process. The newly developed polyurethane surface was smooth and free of surface defects. The in vitro blood test indicated the improved surface was less thrombogenic than before the new techniques were applied, and the surfaces with the surface defects would induce thrombus formation earlier than the smooth surface. The new designs of DHJ, connector system and sealing structure were recommended and discussed.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering - (M.S.)
Discipline thesis:degree_discipline
Biomedical Engineering Committee

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Hui-sun
Contributors dc:contributor
  • Shlomo Gabbay
  • David S. Kristol
  • Clarence W. Mayott

Subjects

dc:subject × 3

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2652

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wang, Hui-sun. An approach to improving the antithrombogenesis of pneumatic diaphragm artificial ventricle : fabrication and design considerations. https://digitalcommons.njit.edu/theses/2652