Back to search

NJIT

The effects of degraded indoor air quality on employees working in high rise office buildings

Abstract

dc:description.abstract

<p>An examination of the effects of poor indoor air quality on workers in high rise office buildings was conducted. These effects are manifested physiologically, psychologically and economically and originate from sources inside and outside the building, as well as from the building's ventilation system. These sources include combustion products, microorganisms, volatile organic chemicals, cigarette smoke and miscellaneous chemicals. Lower productivity and higher absenteeism are the initial results of these effects. If the situation becomes chronic, an erosion of trust between employer and employee can occur which may eventually serve as the basis for litigation, such as worker's compensation claims and suits filed against the building's owner.</p><p>Investigations were conducted following a step by step approach which included a background assessment of the problem, personnel interviews, a walk-through evaluation, environmental monitoring and an examination of the building's ventilation system. With regard to environmental monitoring, carbon dioxide levels were used as an indication of how well the ventilation system was diluting the concentration of other potential contaminants, such as formaldehyde and carbon monoxide. Temperature and humidity were also measured.</p><p>Epidemiological studies were conducted in two high-rise office buildings in New York City. Both studies were characterized by symptoms similar to those associated with poor indoor air quality; eye, nose and throat irritation, headaches, skin rashes, nausea and difficulty in breathing. Air monitoring failed to implicate any point source contaminants (carbon monoxide or formaldehyde). In both studies the ventilation system was identified as the chief source of the problem. Improper mixing and distribution of air, inadequate intake volumes of fresh outdoor air and lack of maintenance were the major contributing factors. These conclusions were corroborated by the air monitoring results which found wide variations in temperature and humidity, and elevated indoor carbon dioxide levels. Also, air flow measurements did not meet original design requirements.</p><p>Primary mitigating procedures were recommended, including proper balancing of the ventilation system, introduction of adequate volumes of fresh air into the office space, and instituting a program of preventive maintenance for the ventilation system.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Management Engineering - (M.S.)
Discipline thesis:degree_discipline
Mechanical and Industrial Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Luongo, Richard Patrick
Contributors dc:contributor
  • Howard Gage

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2839

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Luongo, Richard Patrick. The effects of degraded indoor air quality on employees working in high rise office buildings. https://digitalcommons.njit.edu/theses/2839