Abstract
dc:description.abstract<p>The foam flotation technique was used to remove Cr<sup>3+</sup>, Cr<sup>6+</sup>, Cu<sup>2+</sup>, Zn<sup>2+</sup>, Co<sup>2+</sup>, and Nz<sup>2+</sup> from solution The simulated wastewater contained 20 - 50 ppm of each of these ions. Fe<sup>3+</sup> is added into wastewater as coagulant to produce floc. These dissolved metal ions are adsorbed onto the floc and/or coprecipitate with them. The floc can be then removed from solution by foam flotation. Under optimal conditions, such as pH=6.3 - 7.4, Fe<sup>3+</sup>=160 ppm for hexavalent Chromium or 90 ppm for others and Lauryl Sulfate=90 ppm, removal efficiency of 100% for Cr<sup>6+</sup>, 99.6% for Cu<sup>2+</sup>, 99.5% for Ni<sup>2+</sup>, 99.7% for Co<sup>2+</sup>, and 99.7% for Zn<sup>2+</sup> can be achieved respectively. Mixture of these ions can be removed simultaneously from wastewater by a single step of foam flotation. The results also indicate that polystyrene sulfonate, as polyelectrolyte, can also raise the rate of precipitate foam flotation and screens the effect of ionic strength causing by Na<sub>2</sub>SO<sub>4</sub> which produces the poor efficiency of flotation.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Applied Chemistry - (M.S.)
- Discipline thesis:degree_discipline
- Chemical Engineering, Chemistry and Environmental Science
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Tang, Xue-Jun
- Contributors dc:contributor
-
- George Y. Lei
- Richard Clyde Parker
- Barbara B. Kebbekus
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/2967