<p>A data acquisition and analysis system has been built and tested for the study of laryngeal dynamics: The system uses a computer to control the digitizing rate and to coordinate the pitch prompting for the subject. Tokens of steady state laryngeal vibration are obtained from an electroglottograph when the subject intones a series of computer prompted pitches in a musically scalar sequence. The system digitize the data at a basic rate of 200 samples per laryngeal cycle: This procedure enables the system to perform a modal analysis of laryngeal function: The signal processing and analysis procedure developed displays voice registration phenomena in a completely new and entirely cogent way.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Electrical Engineering - (M.S.)
Discipline thesis:degree_discipline
Electrical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chan, Augustine
Contributors dc:contributor
  • Dale Thorpe Teaney
  • Peter Engler

Subjects

dc:subject × 3

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/3138

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Chan, Augustine. Dynamic laryngeal analysis : hardware and software. https://digitalcommons.njit.edu/theses/3138