Back to search

NJIT

The effects of platelet activating factor (PAF) on the arteriolar average blood velocity and volumetric flowrate in the microcirculation of the hamster cheek pouch

Abstract

dc:description.abstract

<p>The effects of platelet activating factor (PAF) in vessel diameter, average red blood cell (RBC) velocity and volumetric flowrate were studied in twenty-four arterioles located in the cheek pouches of nine male syrian golden hamsters. The observed vessels were between 8-32um in diameter. These vesgs were subdivided further into two groups: 8-17um and the 21-32um group. Fluorescein isothiocyanate (FITC) labeled cells were injected into the hamster to act as velocity tracers. Immediately prior to and for a total of 60 minutes after the topical application of 10<sup>-7</sup>M and 10<sup>-9</sup>M PAF, selected arterioles were video taped periodically in both trans and epi illumination. Diameters were measured by utilizing the video shearing monitor. Average RBC velocities were obtained by using the two slit photometric technique. The volumetric blood flowrates were calculated by assuming that the vessels were rigid cylinders that blood exhibited newtonian behavior and that the flow in the vessels was laminar. It was found that the degree of vasoactivity and the recovery rate of the vessels were dose dependent. In general, application of 10<sup>-9</sup>M PAF resulted in dilation, whereas, application of 10<sup>-7</sup>M PAF resulted in constriction in both diameter groups. Trends for both PAP dosage and arteriole size on the average RBC velocity are the same. During the intial stages of the experiment, a sudden decrease in velocity occurred. This was followed by a gradual rise in velocity to near control value by the end of the experiment. With regards to volumetric flowrates, it was found that following application of 10<sup>-9</sup>M PAF, both arteriolar groups returned to their control flow by the end of the experiment. This was also true for the 8-17um group after 10<sup>-7</sup>M PAF was applied. The 21-32um arterioles, however, only recovered to 82.5% of their control value by the end of the 60 minute observation period.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering - (M.S.)
Discipline thesis:degree_discipline
Chemical Engineering, Chemistry and Environmental Science

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shatynski, Patricia Ann
Contributors dc:contributor
  • David S. Kristol
  • Richard Clyde Parker
  • Arthur B. Ritter

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/3381

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Shatynski, Patricia Ann. The effects of platelet activating factor (PAF) on the arteriolar average blood velocity and volumetric flowrate in the microcirculation of the hamster cheek pouch. https://digitalcommons.njit.edu/theses/3381