Abstract
dc:description.abstract<p>This report describes the analysis and testing of two types of exterior beam-column joints conducted at New Jersey Institute of Technology. The testing program consisted of six beam column joints with varying strength cementing agents in the joint region: normal, high strength and polymer concrete. Half of the specimens contained 1.5 percent by volume of hooked end fibers. The study of the behavior of these beam column joints has indicated 2 cases of failures: a critical region in which the inelastic behavior was controlled by bending and, a critical region in which the inelastic behavior was controlled by high shear.</p><p>From the analysis of the test results, it can be concluded that the Polymer concrete used in the joint region provided:</p><p>1- better bond between matrix. and reinforcement</p><p>2- better confinement in the joint region</p><p>3- a stiffer member</p><p>4- a higher moment capacity</p><p>5- a higher shear strength</p><p>6- more ductility</p><p>7- far less cracking</p><p>8- a significant improvement of the energy dissipation capability than normal and high strength concrete.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Civil Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Civil and Environmental Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kafrouni, Ishac H.
- Contributors dc:contributor
-
- R. John Craig
- C.T. Thomas Hsu
- Methi Wecharatana
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/3537