Abstract
dc:description.abstract<p>The objective of this study was to examine the shear behavior of axially loaded fibrous reinforced concrete short columns under double curavture bending.</p><p>It was suspected that tensile strength rather than compressive strength would better predict the actual behavior of fibrous reinforced short columns. Literature was reviewed to: 1) determine the state-of-the-art of fibrous concrete and 2) column behavior under shear load.</p><p>Interaction Diagrams for conventional concrete and fibrous concrete using ACI-77 and ACI-77 along with modifications for fibrous reinforced columns are given.</p><p>Ten columns were analyzed and experimentally tests; there were three columns without steel fibers (with the same steel reinforcement), and seven columns with steel fibers (also with the same steel reinforcement).</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Civil Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Civil and Environmental Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dib, Nashat Fuad
- Contributors dc:contributor
-
- R. John Craig
- Frederick G. Lehman
- C.T. Thomas Hsu
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/3667