Abstract
dc:description.abstract<p>Separation of protein mixtures by batch and semi-continuous parametric pumping has been examined experimentally. The parapump used generally consist of two columns and four reservoirs. The upper column was packed with an anion exchanger (DEAE-Sepharose) and the lower one with a cation exchanger (CM-Sepharose). There was one top , two middle and one bottom reservoir , with pH equal to P<sub>2</sub>,P<sub>1</sub>,P<sub>3</sub> and P<sub>2</sub> respectively.</p><p>Separation was compared experimentally for the system of He/moglobin-Albumin-CM-Sepharose and DEAE-Sepharose. The results indicate that the two-column parapump has a much higher separation capability than a one-column unit. Separation factors as large as thirty-two were readily attained in the batch system.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Chemical Engineering - (M.S.)
- Discipline thesis:degree_discipline
- Chemical Engineering and Chemistry
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Varuntanya, Chirasakdi
- Contributors dc:contributor
-
- Ching-Rong Huang
- John E. McCormick
- Gordon Lewandowski
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.njit.edu/theses/3685