Abstract
dc:description.abstractThe objective of this thesis is to discuss the suitability of using a extreme fiber concrete tensile stress of 12 * (f'c (exp 1/2) calculated using uncracked section analysis as a limit state criterion for evaluating prestressed concrete highway bridges as a part of required serviceability inspections. This thesis reviews strand fatigue test results as well as fatigue test results of prestressed beams from past experiments. Test results of four new prestressed beam fatigue tests are reported and analyzed. Finally, a recommendation is made that beam fatigue analysis should be based on the stress range of the prestressing strands, unless the calculated extreme fiber concrete tensile stress is limited to less than 3 *f'c(exp 1/2) based on uncracked section analysis.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Engineering
- Grantor dc:publisher
- University of Texas at Austin
- Year dc:date.issued
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Heller, Bryan Earl
- Advisor dc:contributor.advisor
-
- Wood, Sharon L.
Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Distribution Statement A. Approved for public release: Distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/11048