Back to search
Naval Postgraduate School
Capture coefficients of nitrogen on a cryogenically cooled panel
Abstract
dc:description.abstractThe pressure drop method was used to experimentally determine the capture coefficients of nitrogen gas on a flat cryopanel maintained at a temperature of 25°K. The capture coefficients for 300°K nitrogen varied from a maximum of 0.70 for low system gas loads to a minimum of 0.10 for high system gas loads.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor
- Naval Postgraduate School
- Year dc:date.issued
- 1967
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bevan, John Albert
- Advisor dc:contributor.advisor
-
- Pucci, Paul F.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/11759