Monterey, California. Naval Postgraduate School
Experimental Techniques to Determine Ntu of Compact Heat Exchanger Surfaces
Abstract
dc:description.abstractTwo new transient testing techniques were evaluated; the centrold method developed by Kohlmayr and the time zero intercept technique. The zero intercept method was found to be the most promising of the two but is limited to values of N < 2.5. The centrold technique can be used effectively when the value of N is less than 5.0. A heater system made of .001 inch diameter nichrome wire was designed and tested to determine its effect on the transient testing of matrix type heat exchangers. Because the design showed no improvement in the test results and was unreliable its use was discontinued.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1968
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bruno, Marco Joseph
- Advisor dc:contributor.advisor
-
- Pucci, Paul F.
Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/12184