Monterey, California : Naval Postgraduate School
Steady state stream to air testing facility for compact heat exchangers
Abstract
dc:description.abstractA compact heat exchanger testing facility was constructed at the United States Naval Postgraduate School. The testing facility is used to collect heat transfer and friction factor data by the steady state steam to air technique. Heat exchangers with frontal dimensions of up to 12 inches by 12 inches can be tested. The maximum pressure drop which can be produced across the air side of a heat exchanger is 2.5 psi. The testing facility was designed to obtain data for exchanger air side Reynolds numbers from 500 to 10,000. A description of the apparatus, the experimental method and equations and an evaluation are given.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California : Naval Postgraduate School
- Year dc:date.issued
- 1965
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ward, John P.
- Advisor dc:contributor.advisor
-
- Pucci, Paul
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/13110