Steady state stream to air testing facility for compact heat exchangers

Abstract

dc:description.abstract

A compact heat exchanger testing facility was constructed at the United States Naval Postgraduate School. The testing facility is used to collect heat transfer and friction factor data by the steady state steam to air technique. Heat exchangers with frontal dimensions of up to 12 inches by 12 inches can be tested. The maximum pressure drop which can be produced across the air side of a heat exchanger is 2.5 psi. The testing facility was designed to obtain data for exchanger air side Reynolds numbers from 500 to 10,000. A description of the apparatus, the experimental method and equations and an evaluation are given.

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Monterey, California : Naval Postgraduate School
Year dc:date.issued
1965

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ward, John P.
Advisor dc:contributor.advisor
  • Pucci, Paul

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/13110

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Ward, John P.. Steady state stream to air testing facility for compact heat exchangers. Masters thesis, Monterey, California : Naval Postgraduate School, 1965. https://hdl.handle.net/10945/13110