Monterey, CA; Naval Postgraduate School
Characteristics of a pulsed packed, liquid-liquid extraction column.
Abstract
dc:description.abstractAn investigation was conducted of the effect of varying water flow rates and pulse frequency on the performance of a pulsed, packed, liquid extraction column, using the system benzoic acid, toluene, and water. Water was maintained as the continuous phase. It was found that in the range of parameters considered, that the higher the frequency of pulsation and the higher the water flow rate, the lower the height of a transfer unit. The heights of the transfer unit calculated for the conditions considered were 0.97-2.73 feet when referred to the water side and 8.83-40.5 feet when referred to the toluene side for pulse frequency amplitude products of 13 to 65 inches/minute. This represents a considerable improvement over values listed in the literature for unpulsed columns. The writer wishes to express his appreciation for the able assistance and encouragement given him by Professors Carl A. Hering and C.D.G. King of the U.S. Naval Postgraduate School in this investigation.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, CA; Naval Postgraduate School
- Year dc:date.issued
- 1957
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pinzow, Leonard
Subjects
dc:subject × 1Identifiers
dc:identifier.*- OCLC
- ocn640232774