Monterey, California. Naval Postgraduate School
Optimization of an internally finned rotating heat pipe
Abstract
dc:description.abstractA finite element formulation was used to solve the steady-state two-dimensional conduction heat transfer equation in the condenser wall section of an internally finned rotating heat pipe. A FORTRAM program using this method was coupled with the COPES/CONMIN program for sensitivity analysis of design variables and for automated design of the internal heat pipe geometer. With water as the working fluid, numerical results obtained for copper and stainless steel heat pipe condenser sections indicated that for the maximum heat pipe transfer rate, the designer should machine as many fins as the condenser materials and the manufacturing process will allow. A saw tooth profile is preferable to spacing between fins.
Degree
thesis:*- Name thesis:degree_name
- M.S.in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1980
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Davis, William A., Jr.
- Advisors dc:contributor.advisor
-
- Vanderplaats, Garret N.
- Salinas, David
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/17650