Monterey, California. Naval Postgraduate School
Development of a concentric piston transducer for tracking underwater vehicles
Abstract
dc:description.abstractThe use of amplitude and phase shading on a pair of concentric piston radiators has been employed as a means for controlling the acoustic radiation patterns for a small flush face transducer which is intended for use as a 75 kHz sound source in the underwater tracking of vehicles. A description is given of the design, construction and tests of several models of the composite piezoelectric ceramic transducer. Results indicate that this appears to be a feasible method for achieving a principal design goal of a broad beamwidth radiation pattern with a pronounced reduction in source level along the transducer axis. Some additional development is needed for achieving a configuration which might be optimum for production.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Engineering Acoustics
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Engineering Acoustics
- College dc:contributor.school
- Naval Postgraduate School (U.S.)
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1976
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Auns, Vilnis Uldis
- Wilson, O. B.
- Committee member dc:contributor.committeemember
-
- Stentz, D. A.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright is reserved by the copyright owner.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/17732