Massachusetts Institute of Technology
The design, feasibility, and optimization of an ammonia bottoming cycle for power generation.
Abstract
dc:description.abstractThe economic feasibility of utilizing an ammonia bottoming cycle to improve the efficiency of a power plant is studied. The operating parameters of the bottoming cycle are examined to determine the optimum design binary cycle from a lifecycle costs viewpoint. The performance of the combined cycle is compared with that of a representative 'modern' steam plant: TVA's Bull Run. The analysis is based on current economic factors and the climatic conditions at the Bull Run site in Clinton, Tennessee. The optimum combined cycle is $98 million more profitable than the 'Bull Run' plant over the expected lifetime of the plant. The combined cycle also consumes 2.7% less fuel than the unmodified steam plant. Optimization results are also presented for a range of environmental conditions at the plant location. The use of an ammonia bottoming cycle is economically as well as technically feasible provided the ambient water temperature is below 69°F.
Degree
thesis:*- Name thesis:degree_name
- Degree of Mechanical Engineer
- Level thesis:degree_level
- Masters
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 1977
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Fishman, Robert Edward
Identifiers
dc:identifier.*- OCLC
- ocn640257323