Back to search

Pennsylvania State University

A sensitivity study of the critical flow models used in RELAP4/MOD5 blowdown analysis of a General Electric BWR

Abstract

dc:description.abstract

This study utilizes the RELAP4/MOD 5 Computer Code to analyze the effects of critical flow modeling on the thermal-hydraulic transient response of a General Electric boiling water reactor to a major primary coolant line rupture. Included in the study is a presentation of the equations, assumptions, and limitations of the critical flow models available for use in RELAP4. Additionally, an evaluation of a temporary solution to a RELAP4 coding error associated with stagnation properties calculation is presented. The results of this investigation indicate that; (1) a solution to the stagnation properties calculational error that exists in the RELAP4 code, when applied to the Evaluation Model, (RELAP4-EM) provides a conservative evaluation, relative to the Standard model (RELAP4-SM) regardless of which of the five critical flow models available in the code is selected; (2) of the five critical flow models available for use in RELAP$, the Moody model and the Henry-Fauske model are nearly equivalent in the relative degrees of conservatism. Following these models, in order of relative degree of conservatism, are the Modified Momentum/Homogeneous Equilibrium model and the Sonic model; (3) in order to best alleviate the stagnation properties codeing error, the flow areas for the volumes immediately upstream from the recirculation line rupture should be increased such that the area ration (break flow area/upstream volume flow area) is 0.7.

Degree

thesis:*
Name thesis:degree_name
Master of Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Engineering
Grantor dc:publisher
Pennsylvania State University
Year dc:date.issued
1978

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Carle, Mark Vearil
Advisor dc:contributor.advisor
  • Robinson, Gordon E.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/18542

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Carle, Mark Vearil. A sensitivity study of the critical flow models used in RELAP4/MOD5 blowdown analysis of a General Electric BWR. Masters thesis, Pennsylvania State University, 1978. https://hdl.handle.net/10945/18542