Back to search

Monterey, California. Naval Postgraduate School

The effect of condensate inundation on steam condensation heat transfer to wire-wrapped tubing

Abstract

dc:description.abstract

Steam condensation heat transfer measurements were made in a 5-tube test condenser having an additional perforated tube to simulate up to 30 active tubes. Results were obtained for smooth tubes and roped tubes wrapped with wire. A Sieder-Tate equation was used to correlate the inside heat-transfer coefficient. For smooth tubes, a leading coefficient of 0.029 was found, while it was 0.061 for the roped tubes. The average condensing coefficient measured for 30 smooth tubes was 0.59 times the Nusselt coefficient calculated for the first tube. When the smooth tubes were wrapped with wire, this ratio increased up to 0.86. Further, roped tubes without wire experienced a ratio of 0.63, while roped tubes wrapped with wire resulted in a ratio of 0.86. These preliminary data show that wire-wrapped tubes may lead to a significant reduction in condenser surface area.

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Monterey, California. Naval Postgraduate School
Year dc:date.issued
1983

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kanakis, Georgios Dimitriou
Advisor dc:contributor.advisor
  • Marto, P.J.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is reserved by the copyright owner
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/19762

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Kanakis, Georgios Dimitriou. The effect of condensate inundation on steam condensation heat transfer to wire-wrapped tubing. Masters thesis, Monterey, California. Naval Postgraduate School, 1983. https://hdl.handle.net/10945/19762