Back to search

Monterey, California. Naval Postgraduate School

Testing of a shrouded, short mixing stack gas eductor model using high temperature primary flow.

Abstract

dc:description.abstract

An existing apparatus for testing models of gas eductor systems using high temperature primary flow was redesigned and modified to provide improved control and performance over a wide range of gas temperatures and flow rates. Pumping coefficient, temperature, and pressure data were recorded for two gas eductor system models. The first, previously tested under hot flow conditions, consisted of a primary plate with four straight nozzles and a slotted, shrouded mixing stack with two ring diffuser (L/D=2.5). The second was geometrically similar to a model previously tested in cold flow. This model employed a primary plate with four tilted-angled nozzles and a slotted, shrouded mixing stack with two ring diffuser (L/D=1.5). Thermal imagery was used to generalize the data obtained by direct temperature measurement. The validity of cold flow model testing is confirmed. The short stack with tilted-angled primary nozzles is shown to have superior mixing and pumping performance, but to exhibit significantly higher shroud and diffuser surface temperatures.

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Monterey, California. Naval Postgraduate School
Year dc:date.issued
1982

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Eick, Ira James.
Advisor dc:contributor.advisor
  • Pucci, Paul F.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/20375

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Eick, Ira James.. Testing of a shrouded, short mixing stack gas eductor model using high temperature primary flow.. Masters thesis, Monterey, California. Naval Postgraduate School, 1982. https://hdl.handle.net/10945/20375