dc:description.abstractThe application is reported of a United Sensor Corporation 5-hole pressure probe to determine the flow field upstream and downstream of the rotor of a transonic compressor operating to near sonic speeds. Calibration of the probe was reduced to a set of equations to allow off-line data reduction and presentation .using a Hewlett-Packard Model 9830A Calculator system. The flow velocities and angles measured upstream of the rotor were compared with results of compressible flow calculations. Blockage factors were determined which related analytical approximations of the flow incident at the rotor to the measured flow rate. The measurements downstream of the rotor were compared with those of a second probe of different design. Both probes required corrections to their calibrations which were established in an axial annular flow of similar geometric cross section. It is shown that the results derived from the corrected calibration of the 5-hole probe were the more accurate.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Aeronautical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Aeronautical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1975
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Anderson, Dennis Jay
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- OCLC
- ocm640229403