Back to search

Monterey, CA; Naval Postgraduate School

Fiber optic gradient hydrophone construction and calibration for sea trial.

Abstract

dc:description.abstract

A Mach-Zehnder interferometric fiber optic gradient hydrophone, for operation at 632.8 nm wavelength, was designed and constructed for testing in the laboratory. Two individual fiber optic hydrophone sensing coils with 10 m of fiber each were wound and potted on an epoxy mandrel and their respective sensitivities were obtained. They then were mounted on a rigid bar, separated by 10 cm, to form a gradient hydrophone. The sensitivity of the this arrangement then was obtained in a calibrator which allowed the coil pair to be rotated 360°. Since the laboratory interferometric system was too large to be used in the sea trial tests, a second interferometric system, operating at 830 nm wavelength, using diode lasers was designed and constructed. This was mounted in an experimental apparatus designed and constructed for sea trial. A sea trial of a standard Navy type DIFAR hydrophone was conducted to test the effectiveness of the experimental apparatus. The results of the laboratory tests are summarized and discussed and recommendations for further studies are presented.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Systems Technology (Antisubmarine Warfare)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Systems Technology (Antisubmarine Warfare)
Grantor dc:publisher
Monterey, CA; Naval Postgraduate School
Year dc:date.issued
1985

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • MacDonald, Glenn E.
Advisor dc:contributor.advisor
  • Garrett, Steven L.
Committee member dc:contributor.committeemember
  • Carome, Edward F.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/21340

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

MacDonald, Glenn E.. Fiber optic gradient hydrophone construction and calibration for sea trial.. Masters thesis, Monterey, CA; Naval Postgraduate School, 1985. https://hdl.handle.net/10945/21340