Monterey, CA; Naval Postgraduate School
Reciprocity calibration in a plane wave resonator
Abstract
dc:description.abstractA non-standard method for the electroacoustic reciprocity calibration of a condenser microphone is theoretically developed and experimentally employed to calibrate a W.E.640AA laboratory standard microphone. The average experimental calibration so obtained was found to be in absolute agreement with a pressure coupler comparison calibration of the same microphone made at the National Bureau of Standards to within an experimental uncertainty (sigma) of 0.03 dB over the frequency range of 245 to 1470 Hz using a 70 cm. plane wave resonant cavity, and to within an experimental uncertainty (sigma) of ~ .06 dB over the frequency range of 735 to 1470 Hz using a 23 cm. plane wave resonant cavity. Above 1470 Hz., the difference between the resonant plane wave reciprocity calibrations and the pressure coupler comparison calibration increased linearly with frequency to a maximum of ~ .61 dB at 5145 Hz.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Physics (PH)
- Grantor dc:publisher
- Monterey, CA; Naval Postgraduate School
- Year dc:date.issued
- 1985
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Burmaster, Charles Lyman
- Advisor dc:contributor.advisor
-
- Garrett, S.L.
Rights
dc:rights- Statement dc:rights
-
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Dc Identifier Other
- NPS61-86-006