Examining the reliability of a retinal recognition device as database size and the number of enrollment scans are varied for application in Command, Control and Communications (C³)

Abstract

dc:description.abstract

As the amount of sensitive information stored in databases increases due to the current trend to automate Command, Control and Communication (C³) systems, the impact of unauthorized access could be very detrimental to our nation's security. Access control hardware that uses retinal blood vessel pattern recognition may be the solution to the problem. This thesis looks at one retinal pattern recognition device and attempts to determine it's reliability as a function of the data base size stored in memory and the number of enrollment scans averaged together to form the reference template. The database sizes used consisted of 300, 600 or 1200 templates, and the reference templates tested were comprised of 3. 5 or 7 enrollment scans. The applicability of this technology for protecting C³ systems is discussed. This study employed the Eye Dentify 7.5 system developed by Eye Dentify Inc. of Beaverton. Oregon, which performed extremely well by producing a low TYPE I error rate and no TYPE II errors in over 1000 trials. This technology has potential for the protection of C³ systems.

Degree

thesis:*
Name thesis:degree_name
M.S. in Systems Technology
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Systems Technology
Department dc:contributor.department
Command, Control and Communications Academic Group
Grantor
Naval Postgraduate School
Year dc:date.issued
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leigh, Anthony M. Jr.
Advisor dc:contributor.advisor
  • Poock, Gary K.
Committee member dc:contributor.committeemember
  • Neil, D.E.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/21843

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
related terms
citation

Leigh, Anthony M. Jr.. Examining the reliability of a retinal recognition device as database size and the number of enrollment scans are varied for application in Command, Control and Communications (C³). Masters thesis, Naval Postgraduate School, 1986. https://hdl.handle.net/10945/21843