dc:description.abstractThis study concentrates on the empirical characterization of a staggered pin-fin array heat exchanger placed in a modular, rectangular wind tunnel. A full analysis of the heat transfer and pressure drop behavior was conducted on various pin-fin shapes, sizes, and configurations. The study was based on airflow over a wide range of Reynolds numbers in the laminar regime. The empirical data gathered can be used to corroborate and develop better numerical models to characterize the performance of such heat exchangers as well as scale down to the micro level for comparison with micro-heat exchangers.