Back to search

Massachusetts Institute of Technology

Evaluation of non-intrusive monitoring for condition based maintenance applications on US Navy propulsion plants

Abstract

dc:description.abstract

The thesis explores the use of the Non-intrusive Load Monitor (NILM) in Condition Based Maintenance (CBM) applications on US Navy ships as part of the Office of Naval Research Electric Ship Integration (ESI) Initiative. The NILM is a device that measures an electrical component's performance by applying a single voltage and current transducer to a ship's existing power distribution system. The NILM was originally developed to monitor electrical power usage in buildings where it was noticed that it could disaggregate and report the operation of individual loads when many loads were present. The limits of this capability are explored by employing a signal processing script in MATLAB using component data gathered on the USCGC SENECA (WMEC-906). The plausibility of using a few NILMs to provide machinery monitoring information for an entire engineering space, and the resulting opportunity to reduce sensor growth on future Navy ships is explored. Then efforts to monitor naval propulsion plant machinery with the NILM are discussed. Two NILMs were constructed and installed on selected individual components at the Naval Surface Warfare Center Philadelphia DDG-51 Land Based Engineering Site (LBES). Monitoring of the Fuel Oil and Low Pressure Air Service Systems was conducted during a week long certification of the pre-commissioning crew of the USS BAINBRIDGE (DDG-96). Data collected was then used to explore the use of the NILM as a diagnostic device for shipboard systems through the evaluation of mechanical transients in the Fuel Oil system and a test leak inserted into the Low Pressure Air System. Additionally, a brief overview of the Multi-function Monitor (MFM) is provided. The MFM could provide a natural installation point on the ship's power distribution system to monitor multiple loads. Finally, an evaluation of the NILM as an enabling technology for Navy CBM was conducted.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Naval Architecture and Marine Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Ocean Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Greene, William C.

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
  • Distribution Statement A. Approved for public release: Distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/24330

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Greene, William C.. Evaluation of non-intrusive monitoring for condition based maintenance applications on US Navy propulsion plants. Masters thesis, Massachusetts Institute of Technology, 2005. https://hdl.handle.net/10945/24330