Back to search

Massachusetts Institute of Technology

Bolted joint studies in GRP

Abstract

dc:description.abstract

An experimental study was carried out to determine the bolt clampup force relaxation behavior in countersunk, single-lap bolted joints between glass/vinylester resin laminates and steel panels. Additionally, the effect of bolt clampup force relaxation on the bearing strength of such joints was studied. Specially-instrumented bolts were used to measure clampup force relaxation in ten countersunk joint specimens. A 100,000 pound capacity MTS testing machine was used to evaluate the bearing strength in tension of sixteen countersunk bolted joint specimens torqued to four different levels of initial torque, as well as four similar protruding-head bolted joint specimens (at the same levels of torque). The results of the relaxation experiments indicate that clampup force varies widely in nominally identical joints at identical torque levels, by as much as a factor of two. In countersunk bolt joints with sufficiently high initial clampup force, the clampup force relaxed in accordance with the inverse power equation proposed by Shivakumar and Crews for protruding-head bolt joints in graphite/epoxy laminates. Relaxation in the present experiments proceeded faster than in the protruding-head joints studied by Shivakumar and Crews; this is believed to have been due to the relative lack of constraint provided at the GRP surface by the countersunk bolt. The results from the bearing strength experiments suggest that clampup force has only a small beneficial effect on bearing strength in both countersunk and protruding head single-lap joints, when compared to double-lap joints. The reduced effectiveness of clampup force in increasing the bearing strength is believed to be a result of the increased joint rotation and bolt bending inherent in single-lap joints. These phenomena lead to delamination and brooming failure in the GRP, which can be avoided in double lap joints with sufficient bolt clampup force. The countersunk joints failed at a load approximately 20% lower than the protruding head joints.

Degree

thesis:*
Name thesis:degree_name
Degree of Naval Engineer
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Naval Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1994

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fox, David M.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.

Identifiers

dc:identifier.*
OCLC
o640603255

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Fox, David M.. Bolted joint studies in GRP. Masters thesis, Massachusetts Institute of Technology, 1994. https://hdl.handle.net/10945/25716