Computer simulation of a two-phase Capillary Pumped Loop (CPL) using SINDA/FLUINT

Abstract

dc:description.abstract

The heat transfer performance of a prototype capillary pumped loop (CPL) test bed from the U.S. Air Force Phillips Laboratory is modeled using numerical differencing techniques. A commercial computer code was used to create the model and simulate performance over a wide range of operating conditions. Steady state and transient performance were modeled as part of the initial phase of testing in a program designed to evaluate the effectiveness and reliability of capillary pumped loop technology for use in spacecraft thermal control. The performance baseline developed in this phase of testing will serve as the foundation for continued research and development of this technology

Degree

thesis:*
Name thesis:degree_name
M.S. in Mechanical Engineering
Level thesis:degree_level
Masters
Department dc:contributor.department
Mechanical Engineering
College dc:contributor.school
Naval Postgraduate School
Grantor dc:publisher
Monterey, California. Naval Postgraduate School
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ryan, Peter J
Advisor dc:contributor.advisor
  • Kelleher, M.D.

Rights

dc:rights
Statement dc:rights
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/25776

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
related terms
citation

Ryan, Peter J. Computer simulation of a two-phase Capillary Pumped Loop (CPL) using SINDA/FLUINT. Masters thesis, Monterey, California. Naval Postgraduate School, 1997. https://hdl.handle.net/10945/25776