Monterey, California. Naval Postgraduate School
Modelling experimental procedures for manipulator calibration
Abstract
dc:description.abstractA six-degree of freedom manipulator, a PUMA 560, is calibrated using three different measurement systems in order to improve the accuracy of the manipulator. Closed loop kinematic chain modeling theory is presented. Variations in the models for each calibration method are presented. A simulation study is conducted to determine feasibility of the proposed methods. Experimental data is obtained and the actual calibration performed. A comparative analysis between both simulation and experiment and between measurement systems is performed. Various aspects regarding measurement system modeling are discussed. The calibrated kinematic parameters are presented as results.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Mechanical Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1991
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Swayze, William Earl
- Advisor dc:contributor.advisor
-
- Driels, Morris
Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10945/27140