Back to search

Monterey, California. Naval Postgraduate School

PSPICE simulation of total dose effects on composite and single operational amplifiers

Abstract

dc:description.abstract

In this research, continuing evidence that composite operational amplifiers perform better than single amplifiers in both gain bandwidth product and slew rate is presented through an approach of using computer simulation to predict ionizing radiation degradation. This technique examines the use of varying transistor parameters within PSPICE modeled composite and single operational amplifier circuits in order to simulate ionizing radiation. A comparison of the results of this simulation with those of previous research, in which composite and single operational amplifiers were irradiated with a LINAC, verifies that this simulation technique provides a reasonable prediction of a response to ionizing radiation for circuits comprised of radiation hardened components. And, in the process of validating this technique, these simulation results verify that composite operational amplifiers offer an improved bandwidth and a faster slewrate compared to single operational amplifiers

Degree

thesis:*
Name thesis:degree_name
M.S. in Electrical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Electrical Engineering
College dc:contributor.school
Naval Postgraduate School
Grantor dc:publisher
Monterey, California. Naval Postgraduate School
Year dc:date.issued
1994

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Baczuk, Rebecca Lynne
Advisor dc:contributor.advisor
  • Michael, Sherif
Committee member dc:contributor.committeemember
  • Panholzer, Rudolph

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Approved for public release; distribution is unlimited.

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10945/28481

Chain of custody

source
Harvested from
Naval Postgraduate School
Base URL
calhoun.nps.edu/server/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Baczuk, Rebecca Lynne. PSPICE simulation of total dose effects on composite and single operational amplifiers. Masters thesis, Monterey, California. Naval Postgraduate School, 1994. https://hdl.handle.net/10945/28481